Testing & Certifications for InfraStop® Reflective Bubble Insulation

InfraStop® Reflective Insulation products are tested at independent certified laboratories and government-approved laboratories. Testing is performed to current American Society for Testing and Materials (ASTM) standards when an applicable standard exists.

The testing results and technical information below apply to InfraStop® Reflective/Bubble/Bubble/Reflective insulation.

InfraStop® Reflective Insulation Product Specifications

Nominal Thickness 5/16″ (.312)
Weight 0.771 oz./ft²
Temperature Range -30°F to +180°F
Flame Spread Less than 25*
Smoke Development Less than 50*
Perm Rating 0.02**
Puncture Resistance 60 lb./in.***
Vapor Transmission 0.02
Mold and Mildew No Growth
Emittance 0.04
Tensile Strength 3.7 N/mm
Pliability No Cracking
Hot Surface Performance Passed (250°F)

Important: Not for use in direct contact with surface temperatures of 180°F or greater.


* Intertek Testing ASTM Test Method E84
** ASTM Test E96
*** FSTM 101 B Method 2031

Product Standards

Resistance to fungi or bacteria: InfraStop® does not promote the growth of fungi or bacteria.

ICC-ES Evaluation: InfraStop® products have been evaluated under ICC-ES Evaluation Report Number ESR-1362.

InfraStop® reflective insulation products have undergone extensive testing for thermal performance, fire safety, vapor transmission, mold and mildew resistance, emittance, smoke density and physical properties.

Testing & Certification Documents

  • Thermal Performance — ASTM C1363
  • Thermal Performance of Wall Systems — ASTM C1363
  • Thermal Performance — ASTM C335
  • Thermal Performance of Crawl Space — ASTM C1363
  • Hot Surface Performance — ASTM C411
  • Heat Transfer (Heat Flow Up, Down and Horizontal) — ASTM C1363
  • Thermal Performance of Reflective Insulation and Fiberglass in Walls — ASTM C1363
  • Heat Transfer of Air-Handling Ducts with Reflective Insulation
  • Flame Spread and Smoke Density — ASTM E84
  • Mounting Method — ASTM E2599
  • Fungus Resistance — Mil-Std 810B Method 508
  • Pliability Test — ASTM C1224
  • Sound Absorption Test — ASTM C423 and ASTM E795
  • Sound Transmission Loss — ASTM E90 and ASTM E413
  • Water Vapor Transmission — ASTM E96
  • Tensile Strength — ASTM D751
  • Bleeding and Delamination — ASTM C1668
  • Emittance Testing — ASTM C1371
  • Thermal Performance of Water Heater Jackets
  • Intertek: Surface Burning Characteristics of Building Materials — ASTM E84 (Taped Joint Detail), Test Report #3166908SAT-012
  • Intertek: Surface Burning Characteristics of Building Materials — ASTM E84 (Unslit), Test Report #3166908SAT-011
  • R&D Services: Resistance to the Growth of Fungi — ASTM C1338, Test Report #RD072713FR
  • State of California
  • State of California Licensed Insulation Manufacturer
  • State of Minnesota: Filed with Minnesota Insulation Standards Program
  • R&D Services: Emittance Testing
  • R&D Services: Physical Properties — Sheet Width, Length, Pliability, Water Vapor Permeance and Aged Water Vapor Permeance
  • R&D Services: Water Vapor Transmission Test — ASTM E96 (Desiccant Method)

Total Design Calculations

Crawl Space — R-21 Assembly

Two layers of product. The first course is installed to split the 2″ × 10″ joist cavity and the second course is installed on the bottom of the 2″ × 10″ joists, 16″ OC. Heat flow downward.

Construction Component At Framing At Cavity
Inside Air Film 0.68 0.68
Inside Air Film 0.92 0.92
3/4″ Wood Subfloor 0.75 0.75
5/8″ Particle Board Underlayment 0.82 0.82
2″ × 10″ Wood Floor Joists, 16″ OC 10.07 —
9.5″ Air Space — 13.8
InfraStop® Insulation 0.92 0.92
Outside Air Film 4.55 4.55
Total 18.03 21.76

Total Design U: .20/18.03 + .80/21.76 = .0479
Total Design R: 1/.0479 = 20.88

The above assembly R-value of R-21 includes a 4.55 value for the reflective air film.

Exterior Wall Assembly

Product installed on 2″ × 6″ studs, 16″ OC, inside the cavity compressing the R-19 mass insulation batt 3/4″. Heat flow horizontal.

Construction Component At Framing At Cavity
Inside Air Film 0.68 0.68
1/2″ Plaster Board 0.45 0.45
InfraStop® Insulation — *3.87
2″ × 6″ Stud 6.88 —
R-19 Batt — 15.70
1/2″ Plywood 0.62 0.62
Total 8.63 21.32

Total Design U: .14/8.63 + .86/21.32 = .0566
Total Design R: 1/.0566 = 17.67

* Includes the thermal resistance for InfraStop® Insulation and the airspace on one side of the product.

Masonry Wall Assembly

Product installed on 1″ × 2″ furring strips, 16″ OC, to a block or concrete wall. Heat flow horizontal.

Construction Component At Framing At Cavity
Inside Air Film 0.68 0.68
1/2″ Plaster Board 0.45 0.45
InfraStop® Insulation — *3.30
Furring Strips 1.59 —
8″ Concrete Block 1.11 1.11
Total 3.83 7.13

Total Design U: .14/3.83 + .86/5.54 = .1918
Total Design R: 1/.1918 = 5.21

* Includes the thermal resistance for InfraStop® Insulation and the airspace on one side of the product.

Questions About InfraStop® Testing or Product Specifications?

For additional product specifications, testing information or help selecting the appropriate InfraStop® insulation for your application, contact InsulationStop Customer Service at 800-871-0410.

Wishlist 0